Always cut off the power supply first when doing any kind of inspection work. Look closely at those brushes - if they've worn down to less than about a quarter of their original length, it's time to swap them out right away. Take a good look at the commutator too. Are there pits? Scuff marks? Segments that don't line up properly? Those are red flags. When dark carbon builds up on surfaces, that usually means there's been some arcing going on between components, probably because the brushes are getting worn or something isn't aligned correctly. To clean this stuff off, grab some electrical contact cleaner and a soft cloth (nothing scratchy). Never use sandpaper or anything abrasive since that will wreck the delicate copper surfaces underneath. If these problems get ignored, the brushes just keep wearing away faster, leading to all sorts of issues like the motor stopping unexpectedly or running erratically. Worst case scenario? The whole thing could short out internally in those little 12V DC motors we commonly see around.
Check the motor housing carefully for any signs of damage like cracks, dents or corrosion spots. Pay special attention around the terminals since this is where water tends to get inside most often. Try turning the shaft by hand. If it feels gritty, rough or moves unevenly, that's probably a sign the bearings are worn out or contaminated somehow. Take a look at how much the shaft moves back and forth (axial play) and side to side (radial play). Anything over about half a millimeter means the bearings aren't doing their job anymore and need replacing. Make sure all those mounting bolts are tight enough according to specs. Also check if there are any vibration dampening pads installed - these should still be in good shape and not squashed flat over time. When mounts come loose, they throw everything off alignment which puts extra strain on both bearings and brushes. This becomes really important with small 12 volt DC motors because they just don't have much margin for error. Corrosion on the terminals increases resistance between connections, leading to lower voltage reaching components and creating hot spots while the motor runs.
First things first, unplug the motor completely and make sure all capacitors have discharged properly. Grab your multimeter and set it to continuity mode. Touch the probes to different terminal wires. If you hear a beep, great news the circuit is intact. No sound means there's probably a break somewhere in the winding or maybe a loose connection. Now check out the winding resistance. Most small 12V DC motors fall somewhere between 0.5 ohms and 20 ohms. If readings differ more than 15% from what the manufacturer says they should be, or if windings show different values when tested separately, that usually points to problems like partial shorts, breaks in the wiring, or damage from heat exposure. When checking insulation quality, switch your meter to high resistance mode above 1 megaohm range. Put one probe on a terminal and the other against the metal part of the motor housing. Anything under 1 megaohm reading means the insulation isn't doing its job anymore which can lead to dangerous shocks or unexpected short circuits. According to industry reports, about 50% of early failures in these motors come down to issues with either the windings themselves or their insulation breaking down over time.
An open circuit appears as infinite resistance (OL) during continuity testing. Shorted windings manifest as near-zero resistance between terminals—often accompanied by overheating or tripped protection devices. To diagnose ground faults, perform a three-point insulation test:
Testing how equipment performs during actual operation gives a much better picture of its health than just looking at static readings. Start by checking no-load measurements first. Healthy units usually pull around 0.1 to 0.5 amps while keeping their RPM pretty steady, staying within about 10% of what's listed on the spec sheet. Next step is applying some controlled loads gradually either through a dynamometer or calibrated brake system, all while watching for drops in terminal voltage. If there's a voltage drop greater than half a volt when loaded, that often means something inside isn't working right anymore like worn out brushes, corrosion spots on connections, or problems with the windings themselves. Keep an eye on current draw too. Small 12V DC motors generally show a straight line relationship between torque applied and current drawn. Take a motor rated for 5 amps at full power as an example it should be pulling roughly 3.5 amps when running at 70% capacity. Don't forget to check RPM stability with a non-contact tachometer. When RPMs start drifting more than 15%, that typically indicates issues with the commutator wearing down, inconsistent brush pressure across the surface, or imbalanced windings somewhere in the motor.
When motors suddenly draw way more current or stall even when there's not much load on them, it usually means something is wrong mechanically or electrically inside. Binding happens for various reasons like bent shafts, stuck bearings, or junk getting caught in the works, and this causes current spikes that go well beyond normal levels (think over 7.5 amps in a standard 5 amp motor). If a motor stalls despite being lightly loaded, chances are good the armature has taken some damage. For those small 12 volt motors we see everywhere these days, a damaged armature can cut efficiency down by anywhere from 40 to 60 percent, and this shows up as really weak torque output compared to what should be happening. Watch out if the motor draws more than about 80% of its normal current but still only produces half the torque it should - that often points to problems like carbon buildup, insulation breaking down, or brushes not lining up properly. Keep an eye on how hot things get during long runs too. Motors that run consistently hotter than around 65 degrees Celsius will wear out their brushes faster and eventually ruin the insulation. Slow power decline generally comes from brushes wearing away bit by bit over time. But when things start acting strangely - maybe the speed jumps around or it keeps stopping and starting randomly - that's a strong sign there's arcing happening at the commutator or some segments have actually broken off.
2024 © Shenzhen Jixin Micro Motor Co.,Ltd - Privacy policy